G1230 | Galvanised Steel Stop Bead

Interior plaster, 14 mm plaster depth, 7-mesh expanded wings.

view more
Galvanised Steel Stop Bead
Galvanised Steel Stop Bead
Galvanised Steel Stop Bead
Galvanised Steel Stop Bead

Model Number

G1230

Application Area

Interior plaster

Plaster Depth

14 mm

Profile Wings

14x52 mm

Material

Galvanised Steel

Surface Treatment

7-mesh

Product is added to your quote list
Article number Material Thickness Standards Lengths Pack Qty. Pallet Qty.
add to List G12305500 0.50 mm Z275 EN 13658-1 250, 260, 270, 280, 300 cm Bundle: 25 pcs 72 bun.

G1230 mainly used for finishing and reinforcing plaster edges. Provides clean, neat edges at openings, abutment of walls, and ceiling finishes.

Applications

  • Suitable for interior applications.
  • Not suitable for external applications unless secondary protection against corrosion is provided.
  • Not permitted for areas exposed to high moisture and dampness after application. (houses in wooded areas, wet rooms, swimming pools, and domestic bathrooms, etc.)

Compatibility

  • Suitable for lime, cement, lime-cement, or gypsum-based plaster applications.

Materials

  • Manufactured with DX51D+Z galvanised steel strips with zinc coating in accordance with EN 10346.
  • Z275  Zinc coating of 275 g/m² on both sides. Meets EN 13658 parts 1&2 and EN 14353 applications.
  • Z100  Zinc coating of 100 g/m² on both sides Meets EN 14353 applications.
  • Z60    Zinc coating of 60 g/m² on both sides. Meets no standard.

Installation

  • Should be fixed with plaster or render dabs. Adhesive mortars with set accelerators containing chlorides are not suitable for fixing galvanised profiles.
  • Not resistant to corrosion when using topcoats of less than 3mm depth in exterior areas.
  • Should not come into contact with aluminium or stainless steel profiles.
  • Cut with hand plate shears across the wings and a fine-toothed saw across bead noses.
  • Should be fixed in accordance with embedding the bead’s wings into the plaster.

Notice !

Make sure that you choose the most suitable profile material and plaster mortar according to the application area to avoid excessive risks, claims, and consequential damage. To prevent bimetallic corrosion, ensure that all metal components used in a given installation are of the same material type. Please ensure sufficient aeration to prevent corrosion and accelerate the drying time. Avoid damage to beads when trowelling plaster or render. Care should also be taken to prevent mechanical damage to the galvanised coating. The substrate must be dry, clean, dust-free, absorbent, and load-bearing in accordance with the requirements of the plaster coats to be applied. The wall surface must not contain salts or foreign substances and efflorescence must be removed. In general, metal beads should be kept dry and stored flat.

Description

G1230 mainly used for finishing and reinforcing plaster edges. Provides clean, neat edges at openings, abutment of walls, and ceiling finishes.

Applications

  • Suitable for interior applications.
  • Not suitable for external applications unless secondary protection against corrosion is provided.
  • Not permitted for areas exposed to high moisture and dampness after application. (houses in wooded areas, wet rooms, swimming pools, and domestic bathrooms, etc.)

Compatibility

  • Suitable for lime, cement, lime-cement, or gypsum-based plaster applications.

Materials

  • Manufactured with DX51D+Z galvanised steel strips with zinc coating in accordance with EN 10346.
  • Z275  Zinc coating of 275 g/m² on both sides. Meets EN 13658 parts 1&2 and EN 14353 applications.
  • Z100  Zinc coating of 100 g/m² on both sides Meets EN 14353 applications.
  • Z60    Zinc coating of 60 g/m² on both sides. Meets no standard.

Installation

  • Should be fixed with plaster or render dabs. Adhesive mortars with set accelerators containing chlorides are not suitable for fixing galvanised profiles.
  • Not resistant to corrosion when using topcoats of less than 3mm depth in exterior areas.
  • Should not come into contact with aluminium or stainless steel profiles.
  • Cut with hand plate shears across the wings and a fine-toothed saw across bead noses.
  • Should be fixed in accordance with embedding the bead’s wings into the plaster.

Notice !

Make sure that you choose the most suitable profile material and plaster mortar according to the application area to avoid excessive risks, claims, and consequential damage. To prevent bimetallic corrosion, ensure that all metal components used in a given installation are of the same material type. Please ensure sufficient aeration to prevent corrosion and accelerate the drying time. Avoid damage to beads when trowelling plaster or render. Care should also be taken to prevent mechanical damage to the galvanised coating. The substrate must be dry, clean, dust-free, absorbent, and load-bearing in accordance with the requirements of the plaster coats to be applied. The wall surface must not contain salts or foreign substances and efflorescence must be removed. In general, metal beads should be kept dry and stored flat.