PE145 | PVCu Corner Bead with 145g/m² ETAG Mesh

External Thermal Insulation System, Adfors Vertex R117 mesh, 22x22mm extra strong corner bead, mesh width options: 10x23 cm / 10x15cm / 10x10cm / 8x12 cm. Other available color options Minimum Order Quantity: 180.000 meters.

view more
PVCu Corner Bead with 145g/m² ETAG Mesh
PVCu Corner Bead with 145g/m² ETAG Mesh
PVCu Corner Bead with 145g/m² ETAG Mesh
PVCu Corner Bead with 145g/m² ETAG Mesh

Model Number

PE145

Application Area

External thermal insulation

Material

PVC with ETAG 004 mesh

Mesh Weight

145 g/m²

Product is added to your quote list
Article number Standards Corner Bead Wing Profile Weight Mesh Colour Mesh Width Lengths Pack Qty. Pallet Qty.
add to List PE14551W1 ETAG 004 22x22 mm 52 g/m White 10x30 cm 200, 250, 300 cm Box: 50 pcs 50 cts.
add to List PE14552W8 ETAG 004 22x22 mm 52 g/m White 10x23 cm 200, 250, 300 cm Box: 50 pcs 28 cts.
add to List PE14553W8 ETAG 004 22x22 mm 52 g/m White 10x15 cm 200, 250, 300 cm Box: 50 pcs 36 cts.
add to List PE14554W8 ETAG 004 22x22 mm 52 g/m White 10x10 cm 200, 250, 300 cm Box: 50 pcs 42 cts.
add to List PE14555W8 ETAG 004 22x22 mm 52 g/m White 8x12 cm 200, 250, 300 cm Box: 50 pcs 42 cts.

Protects and reinforces the corners of the insulation boards. The profile to create exact edges in thermal insulation systems. The mesh to ensure that there are no cracks in the render.

Applications

ETICS:     External Thermal Insulation Composite System

EIFS:        External Insulation and Facade System

EWI:        External Wall Insulation

Materials

  • Extruded with impact-resistant,%0 recycled content, high-quality rigid PVC, and reinforcement alkali-resistant glass fibre mesh.
  • ETAG 004 certified 145 g/m² reinforcement alkali-resistant E-glass fibre mesh.
  • Strong adhesion of bead and glass fibre mesh with transparent hot-melt glue.

Installation

  • Should be pushed into the first base coat layer.
  • Cut using a fine-toothed hacksaw across bead noses.

Notice !

Make sure that you choose the most suitable profile material and plaster mortar according to the application area to avoid excessive risks, claims, and consequential damage. To prevent bimetallic corrosion, ensure that all metal components used in a given installation are of the same material type. Please ensure sufficient aeration to prevent corrosion and accelerate the drying time. Avoid damage to beads when trowelling plaster or render. Care should also be taken to prevent mechanical damage to the galvanised coating. The substrate must be dry, clean, dust-free, absorbent, and load-bearing in accordance with the requirements of the plaster coats to be applied. The wall surface must not contain salts or foreign substances and efflorescence must be removed. In general, metal beads should be kept dry and stored flat.

Description

Protects and reinforces the corners of the insulation boards. The profile to create exact edges in thermal insulation systems. The mesh to ensure that there are no cracks in the render.

Applications

ETICS:     External Thermal Insulation Composite System

EIFS:        External Insulation and Facade System

EWI:        External Wall Insulation

Materials

  • Extruded with impact-resistant,%0 recycled content, high-quality rigid PVC, and reinforcement alkali-resistant glass fibre mesh.
  • ETAG 004 certified 145 g/m² reinforcement alkali-resistant E-glass fibre mesh.
  • Strong adhesion of bead and glass fibre mesh with transparent hot-melt glue.

Installation

  • Should be pushed into the first base coat layer.
  • Cut using a fine-toothed hacksaw across bead noses.

Notice !

Make sure that you choose the most suitable profile material and plaster mortar according to the application area to avoid excessive risks, claims, and consequential damage. To prevent bimetallic corrosion, ensure that all metal components used in a given installation are of the same material type. Please ensure sufficient aeration to prevent corrosion and accelerate the drying time. Avoid damage to beads when trowelling plaster or render. Care should also be taken to prevent mechanical damage to the galvanised coating. The substrate must be dry, clean, dust-free, absorbent, and load-bearing in accordance with the requirements of the plaster coats to be applied. The wall surface must not contain salts or foreign substances and efflorescence must be removed. In general, metal beads should be kept dry and stored flat.

Downloads

G10105500

Galvanised Steel Corner Bead with PVC nose

0.50 mm | Z275 | Bundle | 2500 pcs